EE370L · Spring 2025 · Partner laboratory work

Control & Measurement Labs

Strain gauges, frequency response, and P/PID motor control

ENGINEERING EVIDENCE / AT A GLANCE

What was done, checked, and documented

Problem

Measure small strain and dynamic electrical responses, then compare feedback-controller behavior with predicted models.

My contribution

Participated in four partner-based laboratory exercises covering strain calibration, frequency-response measurement, and motor-controller implementation.

Engineering tools

Strain gauges, Wheatstone bridge, oscilloscope, function generator, MATLAB, P/PID controller circuits.

Validation method

Compared measured vibration and frequency-response traces, motor rise/settling times, and overshoot with simulations.

Documented result

Observed vibration near 49.3 Hz. Some P-control measurements differed roughly tenfold from simulation; some PID measurements deviated by over 50%.

Limitations

Results come from selected laboratory measurements; full raw waveform datasets and uncertainty estimates are not published here.

PROJECT 08 / 16

In four partner-based instrumentation and control laboratories, we connected models to bench measurements. We calibrated a strain-gauge amplifier and examined bending and vibration of a metal strip, measured RLC and motor frequency responses, then designed proportional and PID motor-speed controllers using MATLAB and physical controller boards. The valuable part was learning where theoretical predictions and measured hardware behavior disagreed.

Engineering details

Challenge

Measure small strain signals and dynamic responses while implementing stable feedback control on real equipment.

Approach

Use a strain-gauge half-bridge and calibrated amplifier, an oscilloscope and function generator for frequency sweeps, MATLAB step-response simulations, and op-amp controller circuits on a DC motor board. Compare rise time, settling time, phase response, and overshoot between models and measurements.

Tools

MATLAB, P/PID feedback, strain gauges, Wheatstone bridge, RLC frequency response, oscilloscope, function generator, DC motor controller board.

Documented outcome

The strain experiment characterized vibration near 49.3 Hz. Increasing proportional gain shortened measured rise and settling times, but P-control experiments showed roughly tenfold differences from the simulation; some PID measurements differed by over 50%. These discrepancies motivated stronger component and setup verification.

Evidence & limitations

Reported waveform values are from a selected lab trace. No raw waveform series or uncertainty statistics are available on this site.