Engineering details
Challenge
Measure small strain signals and dynamic responses while implementing stable feedback control on real equipment.
Approach
Use a strain-gauge half-bridge and calibrated amplifier, an oscilloscope and function generator for frequency sweeps, MATLAB step-response simulations, and op-amp controller circuits on a DC motor board. Compare rise time, settling time, phase response, and overshoot between models and measurements.
Tools
MATLAB, P/PID feedback, strain gauges, Wheatstone bridge, RLC frequency response, oscilloscope, function generator, DC motor controller board.
Documented outcome
The strain experiment characterized vibration near 49.3 Hz. Increasing proportional gain shortened measured rise and settling times, but P-control experiments showed roughly tenfold differences from the simulation; some PID measurements differed by over 50%. These discrepancies motivated stronger component and setup verification.