ProDriver Sim estimates LED-module voltage, driver efficiency, and power from archived configuration tables. Its predicted operating points help identify limits and plan comparisons with future bench measurements.
LED DRIVER DESIGN / VISUAL CASE STUDY
Inside the electrical simulation
These engineering illustrations explain how ProDriver Sim turns archived LED module and driver profiles into predicted voltage, power and efficiency values. Unlike a generic simulation mockup, the curves and operating-point estimates use public source configuration data. They remain modeling inputs and predictions, not independently calibrated measurements.
How the application calculates an operating point
The software loads LED-module and driver tables, interpolates voltage at the requested current, estimates power and efficiency, and reports conditions that violate configured limits. It flags such violations without automatically reducing the current command.
FIG 01 / MODEL FLOW
Functional architecture reconstructed from the public application's implementation. Warning flags are not validated protective actions, and the model does not implement automated thermal derating or physical current clipping.
How current changes predicted module voltage
Two archived HO7 LED-module configuration tables define voltage versus commanded module current. Their piecewise interpolation produces a nominal 44.70 V for the HO7 4800 lm profile at 0.60 A and the HO7 6400 lm profile at 0.80 A.
FIG 02 / PROFILE POINTS
Values are based on public module-profile lookup points. They are not a new laboratory current sweep, verified module I–V characterization, or a claim about optical lumen output.
Predicted output power, input power and efficiency
At nominal currents, the profiles predict 26.82 W and 35.76 W delivered to the respective modules. Input power estimates follow from modeled efficiency, not a physical mains-power measurement.
FIG 03 / POWER MODEL
Derived estimates from the archived BST1 driver and HO7 module tables at nominal 120 V input. The output-power operating points lie below the driver's earliest archived output-power efficiency-table point, so endpoint clamping adds uncertainty. No calibration or hardware efficiency validation is implied.
Engineering details
Challenge
Estimate how electrical operating conditions affect an LED driver and fixture.
Approach
Interpolate LED module voltage from current lookup points, estimate driver efficiency and input power, and flag operating-limit violations. Physical measurements are needed to validate the predictions.
The original public Python application and LED driver/module JSON profiles were recovered. The implementation interpolates module I-V curves, estimates efficiency from driver profile tables, calculates DC output and estimated input power, and flags operating-limit violations. The current simulation reports out-of-range conditions rather than automatically limiting driver output.
Engineering calculations and validation
Using the public model tables, the nominal HO7 4800 lm configuration predicts 44.7 V at 0.60 A, or 26.82 W output. The HO7 6400 lm configuration predicts 44.7 V at 0.80 A, or 35.76 W output. These values are calculated estimates, not recovered bench readings. An independent offline model check, a synthetic test suite, and a verification matrix document what can be reproduced and what still requires instrument testing.
Evidence & limitations
Evidence boundary: The archived application and its configuration tables provide a reproducible electrical model, not verified fixture performance. These figures do not establish input current waveform, AC losses, device lifetime, LED junction temperature, actual delivered lumens, or safe operation outside configured limits.